Phebra METHYLENE BLUE 50 mg/5 mL injection vial Australia - English - Department of Health (Therapeutic Goods Administration)

phebra methylene blue 50 mg/5 ml injection vial

phebra pty ltd - methylene blue, quantity: 50 mg - injection, solution - excipient ingredients: water for injections; hydrochloric acid; sodium hydroxide - methylene blue injection usp is indicated: for the treatment of drug-induced methaemoglobinaemia; for the treatment of idiopathic methaemoglobinaemia (in which structural abnormality of haemoglobin is not present); as a bacteriological strain as a dye in diagnostic procedures such as fistula detection; for the delineation of certain body tissues during surgery.

GE CARESCAPE Central Station Singapore - English - HSA (Health Sciences Authority)

ge carescape central station

ge healthcare pte. ltd. - general hospital - the carescape central station is intended to collect, display and print information from a network, including patient demographics, physiological parameters and waveforms, alarm annunciation and/or other non-medical information from monitors and telemetry systems. physiological parameters and waveforms include electrocardiograph (ecg), pulse oximetry (spo2), invasive blood pressures (ibp), non-invasive blood pressure (nibp), respiration (rr), ventilator (vnt), carbon dioxide (co2), oxygen (o2), mass spectrometry (gas), temperature (temp) and bispectral index (bis). beat to beat patient information for parameters and waveforms from the bedside and telemetry systems can be displayed. patient monitor and telemetry system settings can be adjusted. parameter values derived from patient data can be calculated, displayed, and printed.

GE CARESCAPE Monitor B850 Singapore - English - HSA (Health Sciences Authority)

ge carescape monitor b850

ge healthcare pte. ltd. - general hospital - intended for use on adult, pediatric & neonatal patients. one patient at a time. for monitoring of: • hemodynamic (incl. ecg, st segment, arrhythmia detection, ecg diagnostic analysis & measurement, invasive pressure, non-invasive blood pressure, pulse oximetry, regional oxygen saturation, total hemoglobin concentration, cardiac output (thermodilution & pulse contour), temperature, mixed venous oxygen saturation, central venous oxygen saturation, & surgical pleth index), • respiratory (impedance respiration, airway gases (co2, o2, n2o, and anesthetic agents), spirometry, gas exchange), • neurophysiological status (incl. electroencephalography, entropy, bispectral index, and neuromuscular transmission). intended for use under the direct supervision of a licensed healthcare practitioner, or by personnel trained in proper use of the equipment in a professional healthcare facility.

GE E-BIS Module Singapore - English - HSA (Health Sciences Authority)

ge e-bis module

ge healthcare pte. ltd. - general hospital - is indicated for monitoring the state of the brain by data acquisition of electroencephalograph (eeg) signals of all hospitalized patients. the bispectral index (bis), a processed eeg variable, may be used as an aid in monitoring the effects of certain anesthetic agents. the device is indicated for use by qualified medical personnel only.

GE Healthcare CARESCAPE Monitor B450 Singapore - English - HSA (Health Sciences Authority)

ge healthcare carescape monitor b450

ge healthcare pte. ltd. - general hospital - the device is a multi-parameter patient monitor intended for use in multiple areas & intrahospital transport within a professional healthcare facility. it is indicated for monitoring of: ● hemodynamic (including ecg, st segment, arrhythmia detection, ecg diagnostic analysis & measurement, invasive pressure, non-invasive blood pressure, pulse oximetry, regional oxygen saturation (only for b450 version 3.2), total hemoglobin concentration (only for b450 version 3.2), cardiac output (thermodilution and pulse contour), temperature, mixed venous oxygen saturation, central venous oxygen saturation, & surgical pleth index), ● respiratory (impedance respiration, airway gases (co2, o2, n2o, and anesthetic agents), spirometry, and gas exchange), and ● neurophysiological status (including electroencephalography, entropy, bispectral index, & neuromuscular transmission).

GE Healthcare CARESCAPE Monitor B650 Singapore - English - HSA (Health Sciences Authority)

ge healthcare carescape monitor b650

ge healthcare pte. ltd. - general hospital - intended for use on adult, pediatric,& neonatal patients. one patient at a time. for monitoring of: • hemodynamic (incl. ecg, st segment, arrhythmia detection, ecg diagnostic analysis & measurement, invasive pressure, non-invasive blood pressure, pulse oximetry, regional oxygen saturation, total hemoglobin concentration, cardiac output (thermodilution & pulse contour), temperature, mixed venous oxygen saturation, central venous oxygen saturation, & surgical pleth index), • respiratory (impedance respiration, airway gases (co2, o2, n2o, and anesthetic agents), spirometry, gas exchange), • neurophysiological status (incl. electroencephalography, entropy, bispectral index, and neuromuscular transmission). intended for use under the direct supervision of a licensed healthcare practitioner, or by personnel trained in proper use of the equipment in a professional healthcare facility.

GE Healthcare S5 Anesthesia Monitor Singapore - English - HSA (Health Sciences Authority)

ge healthcare s5 anesthesia monitor

ge healthcare pte. ltd. - anaesthesiology - the s/5 anesthesia monitor with l-ane07 or lane07a software is intended for multiparameter patient monitoring with optional patient care documentation. the s/5 anesthesia monitor with l-ane07 and l-ane07a software is indicated for monitoring of hemodynamic (including arrhythmia and st-segment analysis), respiratory, ventilatory, gastrointestinal/regional perfusion, entropy (state entropy and response entropy) and neurophysiological status of all hospital patients. when the bis module is used with the s/5 anesthesia monitor with l-ane07 and l-ane07a, it is intended for use by personnel trained in its proper use. it is intended for use on adult and pediatric patients within a hospital or medical facility providing patient care to monitor the state of the brain by data acquisition of eeg signals. the bispectral index (bis), a processed eeg variable, and one component of the bis module, may be used in adults as an aid in monitoring the effects of certain anesthetic agents. the s/5 anesthesia monitor with l-

GE Healthcare Solar 8000i Patient Monitor Singapore - English - HSA (Health Sciences Authority)

ge healthcare solar 8000i patient monitor

ge healthcare pte. ltd. - cardiovascular - the solar 8000i patient monitoring system is a multi-parameter physiological patient monitoring system intended for use on adult, pediatric and neonatal patients. it provides uninterrupted monitoring of physiological patient data. it is capable of monitoring and analyzing the following parameters for all patient populations: electrocardiogram, invasive pressure, non-invasive blood pressure, pulse, temperature, cardiac output, respiration, pulse oximetry, venous oxygen saturation, transcutaneous po2 and pco2, co2 and respiratory mechanics. it is capable of monitoring the following parameters for adult and pediatric patient populations: anesthetic agent concentrations, o2, impedance cardiography, electroencephalography and bispectral index. the solar 8000i patient monitoring system also provides physiological data over the unity network.